NAME · USAGE_ · DESCRIPTION · PARAMETERS · EXAMPLES · REFERENCES
SEE_ALSO
vuespec -- Interactively fit model components to input spectra
vuespec
This task fits a model to one or more input spectra; this is the
interactive version of the "autospec" task.
The model is constructed from a set of one or more components
which are stored in an STSDAS binary table, called a component
DataBase. The DataBase may be constructed using the non-interactive
"populate" task.
The spectra can be imported from a variety of common formats,
including ST tables, FITS tables, and IRAF images. If fitting to
more than one spectrum, they need not have the same dispersion
scale. The flux and dispersion arrays for the input spectra are
automatically converted to a set of internal units (PHOTLAM: see
the description of the "flux_unit" parameter below) for fitting.
The results of the fit can be written to an output DataBase;
the physical units are specified interactively.
The various component parameters are fit using a choice of
algorithms to one or more "domains" or portions of the input
spectra. Domains are specified interactively with mouse actions,
although initial domains may be specified with the "fit_domains"
task parameter: the syntax is much like that described in the help
for "ranges" except that no "step size" is allowed, and
sexigesimal numbers are not supported. Specifying domains is a
good way to exclude portions of spectra that would otherwise
difficult or inconvenient to fit.
More detailed help may be accessed through the "Help" button
once this task has been invoked. Alternatively, you can direct
your Web browser to URL http://www.stsci.edu/ASpec.html.
- input = "" [string]
- List of spectra to which the fit will be performed.
- db_intab = "" [string]
- List of DataBase tables from which the component definitions
and initial values will be drawn.
- (db_outtab = "") [string]
- Output DataBase table to contain the fitted components. If
blank, the components will be appended to the (first) input
DataBase table.
- (flux_unit = "FLAMDA") [string]
- System of flux units for the output DataBase table. The
possible choices are: "PHOTLAM|PHOTNU|FLAMDA|FNU|JY|MJY" and
are adopted from the STSDAS "synphot" package. Briefly,
PHOTLAM and PHOTNU both express brightness in units of
equivalent photons/cm**2/s: the former per unit wavelength
(Angstroms), and the latter per unit frequency (Hz). FLAMDA
and FNU both express brightness in units of ergs/cm**2/s:
again per unit Ang or per unit Hz, respectively. JY and MJY
are Janskys and milli-Janskys, respectively.
- (dsprsn_unit = "ANG") [string]
- Dispersion units for the output DataBase table. The possible
choices are: "ANG|NM|MICRON|CM|HZ|MHZ|GHZ|EV|KEV|MEV". The
latter three are expressed as the frequency of a photon with
the equivalent energy in electron volts (eV), or a multiple
thereof.
- (fitpars = "") [pset]
- Parameter set for specifying the fit(s) to be performed.
- (algorithm = "simplex") [string]
- Choice of algorithm for the fit. The possible choices are
"simplex" and "marquadt".
- (fit_toler = 1.e-4) [real]
- Global tolerance to define convergence for fits. The fit is
said to have converged when the merit function changes by less
than this fractional amount.
- (max_iter = 300) [int]
- Maximum number of iterations of the fit algorithm before
stopping; if this limit is reached, a warning message is
issued; the components are written to the output DataBase
in any case.
- (fit_domains = "*") [string]
- String specifying the dispersion domain(s) over which the fit
will be performed; the default is the entire extent of all
input spectra. The domains may be read from an input text file
if the name of the file is specified here, preceeded by an "@"
sign. Separate domains may be specified in this case, one per
line of text, which will result in independent fits to each
domain. The units for the dispersion are taken from the
"dsprsn_unit" parameter.
- (spec_io = "") [pset]
- Parameter set for specifying how to find or construct all of
the attributes of a spectrum: the flux, wavelength, uncertainty,
and mask arrays. The parameters include default column names
for the input spectra if they are tables, or file extension
names if the various arrays are stored in separate files.
These parameters can also be set interactively; type "help
spiopar" for a description of these parameters.
1. Fit a model to a spectrum called "NGC6543.tab" with components
stored in the table "NGC6543_db.tab". Specify the initial
displayed flux units to "FLAMDA" and the dispersion coordinates to
angstroms. Specify one initial fit domain between 4600 and 4800 Ang.
cl> vuespec NGC6543.tab NGC6543_db.tab flux_unit="FLAMDA" \
>>> dsprsn_unit= "ANG" fit_domains="4600:4800"
This package was written by J.D. Eisenhammer, S.J. Hulbert, Z.G.
Levay, and R.A. Shaw. Support for this software development was
provided by the Astrophysics Data Program through NASA grant
NAG5-31859 to STScI.
autospec, populate, ranges, spiopars
Search Form · STSDAS
Maintained by the Science Software Group at STScI
This file last updated on 27 Nov 1996